30. 07. 2026

In brief

  • No — no regulation requires paper. EU Regulation 852/2004 requires records appropriate to the business and leaves the format to the operator.
  • A record must be complete and provable: value, time, place, limit and corrective action — missing or backfilled records are the most common inspection finding.
  • Inspectors accept electronic and automatic records; a 5-year archive that can't be edited after the fact is often trusted more than paper.

No. No regulation requires HACCP temperature records to be kept by hand on paper. EU food hygiene law (Regulation (EC) No 852/2004) requires documentation and records "appropriate to the nature and size of the business" — it says nothing about their form. What matters is that records are complete, truthful and provable; whether they are made with a pen, in a spreadsheet or automatically is up to the operator. Inspectors routinely accept electronic and automatic records — and in practice tend to trust them more than paper.

What the rules actually require

HACCP is built on monitoring critical points — fridge, freezer and hot-holding temperatures — and being able to prove it. The point of a record is not a binder but evidence: that you measured, the values were within limits, and you acted when they weren't. That's why the rules speak of a duty to document, not of a mandatory format. A handwritten log is just one way to meet the duty — historically the most common, but neither the only one nor the safest.

What a record must contain to hold up

  • Measured value, time and place: which fridge, when and how much — with no gaps across days and nights.
  • The limit for that point: so it's clear whether the value complies.
  • Corrective action on a breach: what happened to the stock and what you did — the first thing inspectors look for.
  • A trustworthy instrument: a thermometer or probe with a calibration you can point to.

Incomplete or backfilled records are the most common inspection finding — and fines can run into thousands of euros. What inspectors actually look for in the records we covered in the article on temperature-record inspections and fines.

When paper is enough — and when it's a risk

With one or two fridges and a disciplined routine, a paper log meets the duty. It becomes a risk the moment entries are backfilled: a whole week in the same pen, the same round numbers, nothing from nights and weekends — exactly what a log an inspector doesn't believe looks like. Paper also guards nothing: between entries the temperature can drift for hours with nobody knowing. For a detailed comparison of the two approaches see paper temperature log vs. automation.

What the automatic alternative looks like in practice

A probe goes into each monitoring point and records create themselves, continuously 24/7 — we explain the whole principle here. The HACCP PDF protocol is one click away, a limit breach triggers an alarm (push, e-mail and SMS), and everything sits in a 5-year archive that cannot be edited after the fact — which is why inspectors tend to trust it more than paper. Every probe arrives calibrated with a calibration certificate included and calibration corrections are applied automatically; monitoring runs independently of your site's internet. A small operation starts from €215 one-off + €13 a month — the full price breakdown is here.

To see what automatic records would cost for your operation, configure your points in the pricing configurator — the price shows instantly.

Časté otázky

Yes. The rules don't prescribe a format — they require records to be complete and provable. An electronic record that cannot be edited retroactively and exports to PDF is routinely accepted.

No. An electronic archive is fine as long as you can produce the records at an inspection — print them or show the PDF. An automatic system keeps a 5-year archive, so binders are not your problem.

Formally that's allowed, but the evidence is weak: a spreadsheet can be rewritten at any time and there's no link to a calibrated instrument. An automatic record is created continuously and can't be altered — much stronger evidence.

No single retention period is prescribed — the usual guidance is at least the shelf life of the products, and 1–2 years is common practice. An automatic system keeps a 5-year archive, covering even stricter requirements.